TY - JOUR
T1 - Validation of the BiteStrip screener for sleep bruxism
AU - Shochat, Tamar
AU - Gavish, Anat
AU - Arons, Elena
AU - Hadas, Noam
AU - Molotsky, Alex
AU - Lavie, Peretz
AU - Oksenberg, Arie
PY - 2007/9
Y1 - 2007/9
N2 - Objective: The aim of this study was to validate a small electronic electromyographic device (BiteStrip) designed to screen masseter electromyographic events that indicate sleep bruxism (SB) against traditional masseter electromyographic events (MEMG). Study design: Six SB treatment-seeking patients, 4 obstructive sleep apnea (OSA) patients and 8 symptom-free controls, underwent overnight polysomnography, including MEMG and BiteStrip recordings. Total BiteStrip and MEMG scores and indices (events per hour) based on total recording time (TRT) and total sleep time (TST) were computed. Measures of accuracy, Spearman's rho correlations, and nonparametric group comparisons were performed. Results: BiteStrip average sensitivity was 0.72, average positive predictive value was 0.75. Correlations between left BiteStrip and MEMG total scores, TRT, and TST indices were r = 0.81, r = 0.79, and r = 0.79, respectively. Bland-Altman plots showed good agreement between indices. Significant group differences were observed for total scores and indices. Conclusions: BiteStrip and MEMG scores showed strong relationships. Sensitivity and positive predictive value were acceptable. The BiteStrip is a viable screener for identifying masseter electromyographic events that indicate SB.
AB - Objective: The aim of this study was to validate a small electronic electromyographic device (BiteStrip) designed to screen masseter electromyographic events that indicate sleep bruxism (SB) against traditional masseter electromyographic events (MEMG). Study design: Six SB treatment-seeking patients, 4 obstructive sleep apnea (OSA) patients and 8 symptom-free controls, underwent overnight polysomnography, including MEMG and BiteStrip recordings. Total BiteStrip and MEMG scores and indices (events per hour) based on total recording time (TRT) and total sleep time (TST) were computed. Measures of accuracy, Spearman's rho correlations, and nonparametric group comparisons were performed. Results: BiteStrip average sensitivity was 0.72, average positive predictive value was 0.75. Correlations between left BiteStrip and MEMG total scores, TRT, and TST indices were r = 0.81, r = 0.79, and r = 0.79, respectively. Bland-Altman plots showed good agreement between indices. Significant group differences were observed for total scores and indices. Conclusions: BiteStrip and MEMG scores showed strong relationships. Sensitivity and positive predictive value were acceptable. The BiteStrip is a viable screener for identifying masseter electromyographic events that indicate SB.
UR - http://www.scopus.com/inward/record.url?scp=34547870170&partnerID=8YFLogxK
U2 - 10.1016/j.tripleo.2007.03.009
DO - 10.1016/j.tripleo.2007.03.009
M3 - Article
C2 - 17618147
AN - SCOPUS:34547870170
SN - 1079-2104
VL - 104
SP - e32-e39
JO - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
JF - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
IS - 3
ER -