T1 - Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms
AU - Laufer, Y.
AU - Ries, J. D.
AU - Leininger, P. M.
AU - Alon, G.
PY - 2001
Y1 - 2001
N2 - Background and Purpose. Neuromuscular electrical stimulation is used by physical therapists to improve muscle performance. Optimal forms of stimulation settings are yet to be determined, as are possible sex-related differences in responsiveness to electrical stimulation. The objectives of the study were: (1) to compare the ability of 3 different waveforms to generate isometric contractions of the quadriceps femoris muscles of individuals without known impairments, (2) to compare muscle fatigue caused by repeated contractions induced by these same waveforms, and (3) to examine the effect of sex on muscle force production and fatigue induced by electrical stimulation. Subjects. Fifteen women and 15 men (mean age=29.5 years, SD=5.4, range=22-38) participated in the study. Methods. A portable battery-operated stimulator was used to generate either a monophasic or biphasic rectangular waveform. A stimulator that was plugged into an electrical outlet was used to generate a 2,500-Hz alternating current. Phase duration, frequency, and on-off ratios were kept identical for both stimulators. Participants did not know the type of waveform being used. Torque was measured using a computerized dynamometer: a maximal voluntary isometric contraction (MVIC) of the right quadriceps femoris muscle set at 60 degrees of knee flexion was determined during the first session. In each of the 3 testing sessions, torque of contraction and fatigue elicited by one waveform were measured. Order of testing was randomized. Torque elicited by electrical stimulation was expressed as a percentage of average MVIC. A mixed-model analysis of variance was used to determine the effect of stimulation and sex on strength of contraction and fatigue. Bonferroni-corrected post hoc tests were used to further distinguish between the effects of the 3 stimulus waveforms. Results. The results indicated that the monophasic and biphasic waveforms generated contractions with greater torque than the polyphasic waveform. These 2 waveforms also were less fatiguing. The torques from the maximally tolerated electrically elicited contractions were greater for the male subjects than for the female subjects. Discussion and Conclusion. Muscle torque and fatigue of electrically induced contractions depend on the waveform used to stimulate the contraction, with monophasic and biphasic waveforms having an advantage over the polyphasic waveform. All tested waveforms elicited, on average, stronger contractions in male subjects than in female subjects when measured as a percentage of MVIC. [Laufer Y, Ries JD, Leininger PM, Alon G. Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms.
AB - Background and Purpose. Neuromuscular electrical stimulation is used by physical therapists to improve muscle performance. Optimal forms of stimulation settings are yet to be determined, as are possible sex-related differences in responsiveness to electrical stimulation. The objectives of the study were: (1) to compare the ability of 3 different waveforms to generate isometric contractions of the quadriceps femoris muscles of individuals without known impairments, (2) to compare muscle fatigue caused by repeated contractions induced by these same waveforms, and (3) to examine the effect of sex on muscle force production and fatigue induced by electrical stimulation. Subjects. Fifteen women and 15 men (mean age=29.5 years, SD=5.4, range=22-38) participated in the study. Methods. A portable battery-operated stimulator was used to generate either a monophasic or biphasic rectangular waveform. A stimulator that was plugged into an electrical outlet was used to generate a 2,500-Hz alternating current. Phase duration, frequency, and on-off ratios were kept identical for both stimulators. Participants did not know the type of waveform being used. Torque was measured using a computerized dynamometer: a maximal voluntary isometric contraction (MVIC) of the right quadriceps femoris muscle set at 60 degrees of knee flexion was determined during the first session. In each of the 3 testing sessions, torque of contraction and fatigue elicited by one waveform were measured. Order of testing was randomized. Torque elicited by electrical stimulation was expressed as a percentage of average MVIC. A mixed-model analysis of variance was used to determine the effect of stimulation and sex on strength of contraction and fatigue. Bonferroni-corrected post hoc tests were used to further distinguish between the effects of the 3 stimulus waveforms. Results. The results indicated that the monophasic and biphasic waveforms generated contractions with greater torque than the polyphasic waveform. These 2 waveforms also were less fatiguing. The torques from the maximally tolerated electrically elicited contractions were greater for the male subjects than for the female subjects. Discussion and Conclusion. Muscle torque and fatigue of electrically induced contractions depend on the waveform used to stimulate the contraction, with monophasic and biphasic waveforms having an advantage over the polyphasic waveform. All tested waveforms elicited, on average, stronger contractions in male subjects than in female subjects when measured as a percentage of MVIC. [Laufer Y, Ries JD, Leininger PM, Alon G. Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms.
KW - Fatigue
KW - Neuromuscular electrical stimulation
KW - Torque
KW - Waveform
UR - http://www.scopus.com/inward/record.url?scp=0034936944&partnerID=8YFLogxK
U2 - 10.1093/ptj/81.7.1307
DO - 10.1093/ptj/81.7.1307
M3 - Article
C2 - 11444994
AN - SCOPUS:0034936944
SN - 0031-9023
VL - 81
SP - 1307
EP - 1316
JO - Physical Therapy
JF - Physical Therapy
IS - 7
ER -