Abstract
Purpose: Q-space imaging (QSI) is a diffusion-weighted imaging (DWI) technique that enables investigation of tissue microstructure. However, for sufficient displacement resolution to measure the microstructure, QSI requires high q-values that are usually difficult to achieve with a clinical scanner. The recently introduced “low q-value method” fits the echo attenuation to only low q-values to extract the root mean square displacement. We investigated the clinical feasibility of the low q-value method for estimating the microstructure of the human corpus callosum using a 3.0-tesla clinical scanner within a clinically feasible scan time. Methods: We performed a simulation to explore the acceptable range of maximum q-values for the low q-value method. We simulated echo attenuations caused by restricted diffusion in the intra-axonal space (IAS) and hindered diffusion in the extra-axonal space (EAS) assuming 100,000 cylinders with various diameters, and we estimated mean axon diameter, IAS volume fraction, and EAS diffusivity by fitting echo attenuations with different maximum q-values. Furthermore, we scanned the corpus callosum of 7 healthy volunteers and estimated the mean axon diameter and IAS volume fraction. Results: Good agreement between estimated and defined values in the simulation study with maximum q-values of 700 and 800 cm−1 suggested that the maximum q-value used in the in vivo experiment, 737 cm−1, was reasonable. In the in vivo experiment, the mean axon diameter was larger in the body of the corpus callosum and smaller in the genu and splenium, and this anterior-to-posterior trend is consistent with previously reported histology, although our mean axon diameter seems larger in size. On the other hand, we found an opposite anterior-to-posterior trend, with high IAS volume fraction in the genu and splenium and a lower fraction in the body, which is similar to the fiber density reported in the histology study. Conclusion: The low q-value method may provide insights into tissue microstructure using a 3T clinical scanner within clinically feasible scan time.
| Original language | English |
|---|---|
| Pages (from-to) | 83-93 |
| Number of pages | 11 |
| Journal | Magnetic Resonance in Medical Sciences |
| Volume | 15 |
| Issue number | 1 |
| DOIs | |
| State | Published - 2016 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2015 Japanese Society for Magnetic Resonance in Medicine.
Keywords
- Axon diameter
- Corpus callosum
- Low q-value
- Q-space imaging (QSI)
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
Fingerprint
Dive into the research topics of 'Estimation of the mean axon diameter and intra-axonal space volume fraction of the human corpus callosum: Diffusion q-space imaging with low q-values'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver