Abstract
Analytical protocols for accurate and precise Pb isotope ratio determinations in peat, lichen, vegetable, chimney dust, and ore-bearing granites using MC-ICP-MS and their application to environmental studies are presented. Acid dissolution of various matrix types was achieved using high temperature/high pressure microwave and hot plate digestion procedures. The digests were passed through a column packed with EiChrom Sr-resin employing only hydrochloric acid and one column passage. This simplified column chemistry allowed high sample throughput. Typically, internal precisions for approximately 30ng Pb were below 100ppm (±2σ) on all Pb ratios in all matrices. Thallium was employed to correct for mass discrimination effects and the achieved accuracy was below 80ppm for all ratios. This involved an optimization procedure for the 205Tl/203Tl ratio using least square fits relative to certified NIST-SRM 981 Pb values. The long-term reproducibility (±2σ) for the NIST-SRM 981 Pb standard over a 5-month period (35 measurements) was better than 350ppm for all ratios. Selected ore-bearing granites were measured with TIMS and MC-ICP-MS and showed good correlation (e.g., r=0.999 for 206Pb/207Pb ratios, slope=0.996, n=13). Mass bias and signal intensities of Tl spiked into natural (after matrix separation) and in synthetic samples did not differ significantly, indicating that any residual components of the complex peat and lichen matrix did not influence mass bias correction. Environmental samples with very different matrices were analyzed during two different studies: (i) lichens, vegetables, and chimney dust around a Cu smelter in the Urals, and (ii) peat samples from an ombrotrophic bog in the Faroe Islands. The presented procedure for sample preparation, mass spectrometry, and data processing tools resulted in accurate and precise Pb isotope data that allowed the reliable differentiation and identification of Pb sources with variations as small as 0.7% for 206Pb/207Pb.
| Original language | English |
|---|---|
| Pages (from-to) | 205-215 |
| Number of pages | 11 |
| Journal | International Journal of Mass Spectrometry |
| Volume | 232 |
| Issue number | 3 |
| DOIs | |
| State | Published - 1 Apr 2004 |
| Externally published | Yes |
Keywords
- Accuracy
- Environmental samples
- MC-ICP-MS
- Pb isotope ratios
- Precision
- Sample preparation
- Source assessment
ASJC Scopus subject areas
- Instrumentation
- Condensed Matter Physics
- Spectroscopy
- Physical and Theoretical Chemistry