TY - JOUR
T1 - A higher detection rate for colorectal cancer and advanced adenomatous polyp for screening with immunochemical fecal occult blood test than guaiac fecal occult blood test, despite lower compliance rate. A prospective, controlled, feasibility study
AU - Levi, Zohar
AU - Birkenfeld, Shlomo
AU - Vilkin, Alex
AU - Bar-Chana, Micha
AU - Lifshitz, Irena
AU - Chared, Miri
AU - Maoz, Eran
AU - Niv, Yaron
PY - 2011/5/1
Y1 - 2011/5/1
N2 - Immunochemical fecal occult blood test (FIT) is a new colorectal cancer (CRC) screening method already recommended by the American screening guidelines. We aimed to test the feasibility of FIT as compared to guaiac fecal occult blood test (G-FOBT) in a large urban population of Tel Aviv. Average-risk persons, aged 50-75 years, were offered FIT or G-FOBT after randomization according to the socioeconomic status of their clinics. Participants with positive tests underwent colonoscopy. Participants were followed through the Cancer Registry 2 years after the study. Hemoccult SENSA™ and OC-MICRO™ (three samples, 70 ng/ml threshold) were used. FIT was offered to 4,657 persons (Group A) and G-FOBT to 7,880 persons (Group B). Participation rate was 25.9% and 28.8% in Group A and B, respectively (p < 0.001). Positivity rate in Group A and B was 12.7% and 3.9%, respectively (p < 0.001). Cancer found in six (0.49%) and eight (0.35%) patients of Group A and B, respectively (NS). Cancer registry follow-up found missed cancer in five (0.22%) cases of Group B and none in Group A (NS). The sensitivity, specificity, negative and positive predictive value for cancer in Group A and B were 100%, 85.9%, 100%, 3.9% and 61.5%, 96.4%, 99.8%, 9.1%, respectively. There was increased detection of advanced adenomatous polyp (AAP) by FIT, irrespective of age, gender, and socioeconomic status (Per Protocol: odds ratio 2.69, 95% confidence interval 1.6-4.5; Intention to Screen: odds ratio 3.16, 95% confidence interval 1.8-5.4). FIT is feasible in urban, average-risk population, which significantly improved performance for detection of AAP and CRC, despite reduced participation.
AB - Immunochemical fecal occult blood test (FIT) is a new colorectal cancer (CRC) screening method already recommended by the American screening guidelines. We aimed to test the feasibility of FIT as compared to guaiac fecal occult blood test (G-FOBT) in a large urban population of Tel Aviv. Average-risk persons, aged 50-75 years, were offered FIT or G-FOBT after randomization according to the socioeconomic status of their clinics. Participants with positive tests underwent colonoscopy. Participants were followed through the Cancer Registry 2 years after the study. Hemoccult SENSA™ and OC-MICRO™ (three samples, 70 ng/ml threshold) were used. FIT was offered to 4,657 persons (Group A) and G-FOBT to 7,880 persons (Group B). Participation rate was 25.9% and 28.8% in Group A and B, respectively (p < 0.001). Positivity rate in Group A and B was 12.7% and 3.9%, respectively (p < 0.001). Cancer found in six (0.49%) and eight (0.35%) patients of Group A and B, respectively (NS). Cancer registry follow-up found missed cancer in five (0.22%) cases of Group B and none in Group A (NS). The sensitivity, specificity, negative and positive predictive value for cancer in Group A and B were 100%, 85.9%, 100%, 3.9% and 61.5%, 96.4%, 99.8%, 9.1%, respectively. There was increased detection of advanced adenomatous polyp (AAP) by FIT, irrespective of age, gender, and socioeconomic status (Per Protocol: odds ratio 2.69, 95% confidence interval 1.6-4.5; Intention to Screen: odds ratio 3.16, 95% confidence interval 1.8-5.4). FIT is feasible in urban, average-risk population, which significantly improved performance for detection of AAP and CRC, despite reduced participation.
KW - FIT
KW - G-FOBT
KW - colorectal cancer
KW - fecal occult blood test
KW - guaiac
KW - immunochemical test
KW - screening
KW - sensitivity
KW - specificity
UR - http://www.scopus.com/inward/record.url?scp=79953169888&partnerID=8YFLogxK
U2 - 10.1002/ijc.25574
DO - 10.1002/ijc.25574
M3 - Article
C2 - 20658527
AN - SCOPUS:79953169888
SN - 0020-7136
VL - 128
SP - 2415
EP - 2424
JO - International Journal of Cancer
JF - International Journal of Cancer
IS - 10
ER -